MMB CLI (Command Line Interface) Operations
Example: When IOU#3 is to be added to Partition#2
# hotadd partition 2 IOU 3
Are you sure to continue adding IOU#3 to Partition#2? [Y/N] Y
DP operation start (1/3)
Assigning IOU#$ to partition#$ (2/3)
Power on IOU#$(3/3)
Adding IOU#3 to Partition#2 has been completed successfully.
#
(4) Message
The following table lists the messages which are displayed in this CLI.
For details of the messages, see the PRIMEQUEST 2000 Series Message Reference (C122-E178EN).
Are you sure to continue adding [SB#%d|IOU#%d] to partition#%d? [Y/N]:
DP operation start (1/5)
Assigning SB#%d to partition#%d (2/5)
Testing SB#%d (3/5)
Reconfiguring partition#%d (4/5)
Onlining added Memory/CPU (5/5)
DP operation start (1/3)
Assigning IOU#%d to partition#%d (2/3)
Power on IOU#%d(3/3)
Adding [SB#%d|IOU#%d] to partition#%d has been completed successfully.
The specified [SB#%d|IOU#%d] is not present.
The specified [SB#%d|IOU#%d] is power-on.
The specified Partition#%d is no Home.
Hot-add [SB#%d|IOU#%d] failure.
Unable to hot-add SB due to firmware mismatch.
Unable to hot-add SB due to SB revision mismatch.
Unable to hot-add SB due to CPU mismatch.
Unable to hot-add SB due to DIMM mismatch.
Unable to power on the DP test partition.
Unable to power off the DP test partition.
Chekc DP Unit Error
Unable to onlining the DP target bmc.
Unknown Error Code =0xXX
Failed to execute hotadd partition command.
Unable to execute this command on a standby MMB.
Hot-add [SB#%d|IOU#%d] failed.
Failed to execute DP operation. Fatal error occurred.
Unable to power on the IOU.
Unable to power on the PCIBox.
Failed to create DP test partition.
Failed to execute DP operation. Partition is stopped.
DP sequence timeout: added SB power on failure
DP sequence timeout: SB hot-add OS failure
DP sequence timeout: SB hot-add request failure
DP sequence timeout: QPI connection failure
BIOS Error Code =0xXX
The specified [SB#%d|IOU#%d] is not free or reserved.
DP can't be enabled, because of no DP license
DP feature is disabled.
Unable to execute DP command while other DP command is running
Unable to execute DP command due to previous failure.
Unable to execute DP command because OS is not ready for DP operation