MMB CLI (Command Line Interface) Operations
When the partition specified by the parameter is not configured, the partition which is not configured is
ignored.
When the power supply for the specified partition is already turned on, processing for such partitions is not
done.
Partition Operator can operate only the partition to be managed.
When the parameter which contains the partitions other than those to be managed is specified, an error
message is displayed and the specified partition cannot be operated.
Privilege: Administrator, Operator, Partition Operator (Only the partition to be
managed)
(1) Input format
power on {partition} [ all | <partition#> [, | -] <partition#>]
(2) Option
Partition: Turn on the power of the partition which specifies the partition number.
When there is no power supply to the chassis, before turning on the power of the partition, turn on
the power supply of the chassis and then turn on the power supply of the specified partition.
This parameter is optional. The default parameter is processed as the specified partition
parameter. Therefore, it is necessary to specify the partition.
Partitions are specified as follows.
all (All defined partitions) specified
Specifies Partition numbers by delimiting with comma
Specifies with the range of partition number
(3) Usage example
None
(4) Message
The following table lists the messages which are displayed in this CLI.
For details of the messages, see the PRIMEQUEST 2000 Series Message Reference (C122-E178EN).
The specified parameter is invalid.
The specified partition number is invalid.
Unable to power on the partition#%d due to CPU mismatch between SBs.
Unable to power on the partition#%d due to DIMM does not satisfy requirements of Mirror Mode.
Unable to power on due to mismatch between supply voltage and input voltage.
Unable to power on the partition#%d due to abnormal DIMM composition.
Unable to power on the partition#%d due to abnormal SB composition.
Unable to power on the partition#%d due to abnormal VRM composition.
Unable to power on the partition#%d.
Command Failed. Code=0x%04X, 0x%02X
Unable to execute this command on a standby MMB
Unable to execute this command because the system is under maintenance.
Unable to execute this command because the Partition#x is under maintenance.
The Power On failed, because of switching the Home SB.
Please execute it after a while again.
Unable to power on the Partition#n because you have not authority to operate this partition.
Unable to power on the partition(s) because the partition which does not have authority to you is included
in the specified parameter.