MMB Web-UI (Web User Interface) Operations
Items
Description
This item becomes effective at the time of the Power ON by the schedule.
Specifies within the range of 0~9999 seconds.
Default value is 0 seconds.
(attention)
Other start processing is not executed until the processing of Partition Power On
Delay ends. However, when Power On by the schedule driving is done for the
period of Power on delay by the AC power supply turning on (includes restoration
powe), Power On delay by the AC power supply turning on (includes restoration
powe) is given to priority, and Power on delay by Power On by the schedule driving
is disregarded.
Altitude
Sets the altitude where PRIMEQEST 2000 series system is installed or placed.
· Altitude < 1000 m
· 1000 m <= Altitude < 1500 m
· 1500 m <= Altitude < 2000 m
· 2000 m <= Altitude
Default value is Altitude < 1000 m.
Setting error of altitude condition is possible up to ±100m.
PSU Redundant Mode
Sets whether PSU is redundantly operated.
· Redundant
· Non-redundant
When Power Feed Mode is Single, it is by default Non-Redundant.
When Power Feed Mode is Dual, it is always Redundant.
Reserved SB Force
Power Off Wait
While switching to Reserved SB, sets the maximum standby time till the start of
force power off of partition which includes the concerned SB. Specifies within the
range of 0~99 minutes.
Default is 10 minutes.
System Power Save
Control
Sets enable/disable for Power Saving function for entire system.
· Enable
· Disable
Power Saving function supports only PSU_P 200V.
Default is Disable.
System Power Saving
Threshold
Sets the power consumption threshold (Limit value) of entire system.
Minimum value is 300W.
Maximum value is as shown below.
· PRIMEQUEST 2400E : 8640W
· PRIMEQUEST 2800E/B : 8640W
Setting is possible only when System Power Save Control is Enable, gray-out at
the time of disable.
Default value is the maximum value of each model.
TABLE 1.33 [System Setup] window button
Buttons
Description
Apply
When items such as [Power Feed Mode] and [Power Restore Policy] are specified and [Apply]
button is clicked, the information is set.
Cancel
When [Cancel] button is clicked, returns to the original status without setting the changed or
input items.