Fujitsu C122-E177-01EN Computer Hardware User Manual


 
MMB Web-UI (Web User Interface) Operations
Items
Description
Manual(C122-E175EN)
Device ID Displays the Device ID of the PCI Card.
Remarks
ID uniquely allocated in device of manufacturer.
For details of the ID, see the PRIMEQUEST 2000 Series Administration
Manual(C122-E175EN)
PCIeSW
PCIeSW
Displays the number of PCIeSW.
Status Displays the status of PCIeSW.
OK
Warning
Failed
PCIeSW#1
Same as PCIeSW#0
Voltage
Voltage
Sensor
Displays the Voltage sensor type.
P1.8VL(*1)
P1.0VL(*1)
P2.5VL(*2)
P1.2VL(*2)
P0.8VL(*2)
P0.67VL(*2)
P3.3V(*3)
P1.8V_PCIEX#0(*1)
P1.8V_PCIEX#1(*1)
P1.8V(*2)
P0.9V_PCIEX#0(*3)
P0.9V_PCIEX#1(*3)
*1: IOUL,*2: IOUF,*3: IOUL/IOUF commonness
Voltage
Displays the current power voltage.
Threshold
Warning
(Low/High)
Lower and upper limits of the warning-level voltage.
Displays “ ”, when the threshold is not set.
Displays the power voltage in the last two decimal places.
Critical
(Low/High)
Lower and upper limits of the critical-level voltage.
Displays “ ”, when the threshold is not set.
Displays the power voltage in the last two decimal places.
TABLE 1.162 Button of [IOB#x] Screen
Buttons
Description
Status Clear
Clears the error status of IOU#x
1.7.16 [DU] Menu
As for the display, the operation is the same as the PRIMEQUEST 2400E/2800E model. Refer to chapter
1.2.15.