Page 38 Epson Research and Development
Vancouver Design Center
S1D13705 Programming Notes and Examples
X27A-G-002-03 Issue Date: 02/01/22
Figure 7-1: Relationship Between the Default Mode Screen Image and the Image Refreshed by S1D13705
From the programmers perspective the memory is laid out as shown on the left. The
programmer accesses memory exactly as for a panel of with the dimensions of 240x320
setup to have a 256 pixel horizontal stride. The programmer sees memory addresses
increasing from A->B and from B->C.
From a hardware perspective the S1D13705 always refreshes the LCD panel in the order
B->D and down to do A->C.
256
256
image seen by programmer
= image in display buffer
320
portrait
window
320
240
AB
C
D
D
C
B
A
240
start
address
portrait
window
display
E
E
image refreshed by S1D13705
start
address
physical