Page 10 Epson Research and Development
Vancouver Design Center
S1D13705 Windows® CE 2.x Display Drivers
X27A-E-001-03 Issue Date: 01/06/07
Installation for CEPC Environment
Once the NK.BIN file is built, the CEPC environment can be started by booting either from a
floppy or hard drive configured with a Windows 9x operating system. The two methods are
described below.
1. To start CEPC after booting from a floppy drive:
a. Create a bootable floppy disk.
b. Edit CONFIG.SYS on the floppy disk to contain only the following line:
device=a:\himem.sys
c. Edit AUTOEXEC.BAT on the floppy disk to contain the following lines:
mode com1:9600,n,8,1
loadcepc /B:9600 /C:1 c:\nk.bin
d. Copy LOADCEPC.EXE and HIMEM.SYS to the bootable floppy disk. Search for
the loadCEPC utility in your Windows CE directories.
e. Copy NK.BIN to c:\.
f. Boot the system from the bootable floppy disk.
2. To start CEPC after booting from a hard drive:
a. Copy LOADCEPC.EXE to C:\. Search for the loadCEPC utility in your Windows
CE directories.
b. Edit CONFIG.SYS on the hard drive to contain only the following line:
device=c:\himem.sys
c. Edit AUTOEXEC.BAT on the hard drive to contain the following lines:
mode com1:9600,n,8,1
loadcepc /B:9600 /C:1 c:\nk.bin
d. Copy NK.BIN and HIMEM.SYS to c:\.
e. Boot the system.