Fujitsu FI-6800 Scanner User Manual


 
Index
Chapter 9 Operational Settings
Appendix
Glossary
Introduction
Contents
TOP
214
How to Load
Documents
Configuring
the Scan
Settings
How to Use
the Operator
Panel
Various Ways
to Scan
Daily Care
Troubleshooting
Replacing
Consumables
Scanner
Overview
Operational
Settings
Example 1:
z Specified position: Left
Selected range = Disable, Start = 50 mm, End = 200 mm
z Specified position: Middle
Selected range = Enable, Start = 50 mm, End = 200 mm
z Specified position: Right
Selected range = Disable, Start = 50 mm, End = 200 mm
Multifeed is detected only for the areas in light blue.
End
(Left/Middle/Right)
Displays the end point of the detection by
the length from the leading edge of the
document.
Configurable area: 0 to 510 mm (in
increments of 2 mm), Start < End
z When both [Start] and [End] are set to "0", multifeed
detection is performed for the whole area regardless of
whether it is enabled or disabled.
z To disable multifeed detection for the whole document,
select [Disable] and set the start position to "0" and the
end position to be equal to or longer than the
document length.
z If the start position is set larger than the document
length: with [Disable], the whole range covering the
entire document length will be checked; with [Enable],
the multifeed detection will be disabled.
z To detect multifeeds, the detection range must be at
least 8 mm in length.
Configure the settings so that the value of the end
position minus the start position is 6 mm or more.
z You can also set the start and the end positions by one
of the following ways:
- Create a square or rectangle to indicate the
detection range by dragging your mouse pointer on
the displayed image in the dialog box.
- Drag the handle for the detection range to change
the start and end positions using the mouse pointer
on the displayed image in the dialog box.
Range Description
35
35
35
60 60
50
200
Unit: mm
Feeding direction