Fujitsu FI-6800 Scanner User Manual


 
Index
Chapter 9 Operational Settings
Appendix
Glossary
Introduction
Contents
TOP
215
How to Load
Documents
Configuring
the Scan
Settings
How to Use
the Operator
Panel
Various Ways
to Scan
Daily Care
Troubleshooting
Replacing
Consumables
Scanner
Overview
Operational
Settings
Example 2:
z Specified position: Left
Selected range = Disable, Start = 0 mm, End = 300 mm or more
z Specified position: Middle
Selected range = Enable, Start = 0 mm, End = 0 mm
z Specified position: Right
Selected range = Disable, Start = 0 mm, End = 0 mm
Multifeeds are detected only for the areas in light blue.
Example 3: (Bad example)
z Specified position: Left
Selected range = Disable, Start = 310 mm, End = 400 mm
z Specified position: Middle
Selected range = Enable, Start = 320 mm, End = 450 mm
z Specified position: Right
Selected range = Enable, Start = 100 mm, End = 102 mm
Since the detection range (length) is less than 8 mm,
multifeeds cannot be detected correctly.
When detecting the overlapping of documents, the multifeed
detection rate may drop if the documents are glued tightly or
attached together by static electricity.
35
35
35
60 60
300
Unit: mm
Feeding direction
35
35
35
60 60
300
2
100
Unit: mm
Feeding direction