HP (Hewlett-Packard) C2039A Printer User Manual


 
Replacing the High Voltage Contact
Assembly/Feed Guide Assembly
The Toner Cartridge Guide Plate and the High Voltage Contact
Assembly/Feed Guide Assembly must be installed together.
Allow plenty of time to perform this procedure because several
iterations of the process may be necessary.
1 Set the contact assembly over its mounting holes.
2 Slide the Toner Cartridge Guide Plate into position on a
diagonal line (see Figure 6-57).
3 Working the two parts together, lift the rear of the HVCP to
provide enough clearance to install the Guide Plate.
4 When the Guide Plate is in position, press it into place on the
sheet metal.
5 Press the HVCP into its mounting slots.
6 Install the Laser Shutter Pivot Pin and test the Laser Shutter
for free operation.
7 Replace the gear cover (see Figure 6-56).
Figure 6-57 Orientation of HVCP and Left Guide Plate
6-68 Removal and Replacement