IXF1104 4-Port Gigabit Ethernet Media Access Controller
Datasheet 147
Document Number: 278757
Revision Number: 007
Revision Date: March 25, 2004
t
SU.STA
Start setup time 4.7 – µs
t
HD.DAT
Data in hold time 0 – µs
t
SU.DAT
Data in setup time 200 – ns
t
R
Inputs rise time – 1.0 µs
t
F
Inputs fall time – 300 ns
t
SU.STO
Stop setup time 4.7 – µs
t
DH
Data out hold time 100 – ns
t
WR
Write cycle time – 10 ms
Table 53. I
2
C AC Timing Characteristics (Sheet 2 of 2)
Symbol Parameter Min Max Units