Nortel Networks 2500 Series Switch User Manual


 
Configuring PoE switch parameters using the CLI 159
poe poe-pd-detect-type
{802dot3af | 802dot3af_and_legacy | Unit}
The poe poe-pd-detect-type command is executed in the Global
Configuration command mode.
ATTENTION
You must ensure that this setting is the correct one for the IP appliance you
use with the switch. Please note this setting applies to the entire switch, not
port-by-port. So, you must ensure that this setting is configured correctly for all
the IP appliances on a specified switch.
describes the parameters and variables for the poe poe-pd-detect-type
command.
Table 34
poe poe-pd-detect-type command parameters and variables
Parameters and
variables
Description
802dot3af |
802dot3af_and
_legacy
Sets the detection method the switch use to detect power needs of devices
connected to front ports:
802dot3af
802dot3af_and_legacy
ATTENTION
The default setting is 802dot3af. Ensure that the power detection method
you choose for the Ethernet Routing Switch 2500-PWR matches that used
by the IP devices you are powering.
Unit
Set the unit in stack to apply the detection method.
poe poe-power-usage-threshold command
The poe poe-power-usage-threshold command lets you set a
percentage usage threshold above which the system sends a trap
for each Ethernet Routing Switch 2500-PWR. The syntax for the poe
poe-power-usage-threshold command is:
poe poe-power-usage-threshold {<1-99> | Unit}
The poe poe-power-usage-threshold command is executed in the
Global Configuration command mode.
Nortel Ethernet Routing Switch 2500 Series
Overview — System Configuration
NN47215-500 (323162-B) 02.02 Standard
4.1 19 November 2007
Copyright © 2007, Nortel Networks
.