284 Configuring the switch using Device Manager
Field Description
transmission is enabled for particular ports,
the suggested default throttling period is
5 seconds.
RemTablesLast
ChangeTime
The value of the sysUpTime object
(defined in IETF RFC 3418) at the
time an entry is created, modified, or
deleted in tables associated with the
lldpRemoteSystemsData objects, and
all LLDP extension objects associated
with remote systems. An NMS can
use this object to reduce polling of the
lldpRemoteSystemsData objects.
RemTablesInserts The number of times the complete
set of information advertised by a
particular MSAP is inserted into tables
contained in lldpRemoteSystemsData and
lldpExtensions objects. The complete set
of information received from a particular
MSAP is inserted into related tables. If
partial information cannot be inserted
for a reason such as lack of resources,
all of the complete set of information is
removed. This counter is incremented only
once after the complete set of information
is successfully recorded in all related
tables. Any failures occurring during
insertion of the information set, which
result in deletion of previously inserted
information, do not trigger any changes
in lldpStatsRemTablesInserts because
the insert is not completed yet or in
lldpStatsRemTablesDeletes, because the
deletion is only a partial deletion. If the
failure is the result of a lack of resources,
the lldpStatsRemTablesDrops counter is
incremented once.
Nortel Ethernet Routing Switch 2500 Series
Overview — System Configuration
NN47215-500 (323162-B) 02.02 Standard
4.1 19 November 2007
Copyright © 2007, Nortel Networks
.