Toshiba VF-AS1 Power Supply User Manual


 
E6581528
F-53
6
Pattern operation switching output (output terminal function: , )
If the pattern operation switching output function is selected (activated), a signal is put out on completion of all the
predetermined patterns of operation. When there is no operation command left to be entered or the pattern
operation selection signal changes, the output terminals are turned off.
Terminal
symbol
Title Function
Adjustment
range
Example of setting
OUT1 
Output terminal
function selection 1
~
 (Pattern operation finished – ON signal)
or
 (Pattern operation finished – OFF signal)
Note: To put out signals to the terminal OUT2, select the parameter .
Note:
Pattern operation groups should be selected by terminal input.
If no signal is put out from any pattern operation signal (all terminals are turned off), or after the pattern
operation is completed, the system returns to the normal operation mode.
When two or more pattern group numbers are entered simultaneously, the pattern group operations are
performed in ascending order and automatically switched to one another. In this case, it may take about
0.06 seconds to search for each pattern.
Do not turn on the operation signal in 10 ms after turning on pattern operation selections 1 and 2 when the
machine is at rest. Or the normal operation frequency may be output.
(1)
Pattern operation input 1 (S1-CC)
Pattern operation input 2 (S2-CC)
ON
ON
(1)
: Pattern group 1 in operation
(2)
: Pattern group 2 in operation
<Parameter setting>

=

(Pattern operation selection 1)

=

(Pattern operation selection 2)
Pattern run operation
(2)
6.32 Preset speed mode
 ~  : Preset speed operation modes
For more details, refer to Section 5.12.