Toshiba VF-AS1 Power Supply User Manual


 
E6581528
J-8
10
Selection table of separate-type options
Applicable
Motor (*6)
500V 600V 690V
Inverter
model
Input AC
reactor
(PFL)
(*4,5)
Zero-phase
Core
( *1 )
Dynamic brake
drive circuit
(GTR7)
(*2)
Motor end
surge voltage
suppression
filter (*3,5)
Sinusoidal
output
Voltage filter
(*5)
Control
power
supply
backup
1.5kW 2HP
VFAS1-5015PM
In preparation In preparation
2.2kW 3HP
VFAS1-5022PM In preparation In preparation
3kW
– –
VFAS1-5030PM In preparation In preparation
4kW 5HP
VFAS1-5040PM In preparation In preparation
5.5kW 7.5HP
VFAS1-5055PM In preparation In preparation
7.5kW 10HP
VFAS1-5075PM In preparation
RC9129 Built-in
In preparation
CPS002Z
1.5kW 2HP 2.2kW
VFAS1-6022PL In preparation
2.2kW 3HP 3kW
VFAS1-6030PL In preparation
4kW 5HP 5.5kW
VFAS1-6055PL In preparation
5.5kW 7.5HP 7.5kW
VFAS1-6075PL In preparation
7.5kW 10HP 11kW
VFAS1-6110PL In preparation
11kW 15HP 15kW
VFAS1-6150PL In preparation
15kW 20HP 18.5kW
VFAS1-6185PL In preparation
18.5kW 25HP 22kW
VFAS1-6220PL
PFL-6038S
In preparation
22kW 30HP 30kW
VFAS1-6300PL In preparation
30kW 40HP 37kW
VFAS1-6370PL In preparation
37kW 50HP 45kW
VFAS1-6450PL
PFL-6067S
In preparation
45kW 60HP 55kW
VFAS1-6550PL PFL-6095S In preparation
55kW 75HP 75kW
VFAS1-6750PL –
75kW 100HP 90kW
VFAS1-6900PL –
90kW 125HP 110kW
VFAS1-6110KPC
PFL-6151S
110kW 150HP 132kW
VFAS1-6132KPC
MSL-4215T
132kW - 160kW
VFAS1-6160KPC
PFL-6219S
RC9129 Built-in
SWF-6200K
160kW 200HP 200kW
VFAS1-6200KPC
PFL-6264S
MSL-4314T
185kW 250HP 250kW
VFAS1-6250KPC
250kW 350HP 315kW
VFAS1-6315KPC
PFL-6428S
PB7-6300K
MSL-4481T
SWF-6400K
315kW 450HP 400kW
VFAS1-6400KPC
PFL-6300S x 2
400kW 550HP 500kW
VFAS1-6500KPC
MSL-4759T
500kW 700HP 630kW
VFAS1-6630KPC
PFL-6428S x 2
FT-1KM
F200160PB
PB7-6400K
MSL-41188T
SWF-6800K
CPS002Z
(*1): This filter needs to be wound 4 turns or more around with the input side power line. This filter can be used for the output
side in the same manner. For the wire whose size is 22 mm
2
or more, install at least 4 filters in series. Round type (Model:
RC5078) is also available.
(*2): To use the VFAS1-6200KPC or larger in combination with an external braking resistor , a braking unit (PB7) with a built-in
braking resistor drive circuit is also needed.
(*3): Each MSL model is an output-dedicated surge suppression reactor, and as a guide, use a cable 100m or less in length (or
50m or less for a shielded cable) to connect the inverter to the motor, although allowable cable lengths vary according to the
input voltage.)
(*4): Input AC reactor (PFL or 3% AC reactor) is mandatory for VFAS1-6110KPC and above.
(*5): Consult factory for North American market (end of type form is -HN). 3% is the typical recommended input AC reactor
impedance, 5% is the maximum value. Input AC reactors are mandatory for VFAS1-6110KPC and above.
(*6): If you need built-in EMC filter up to 10HP for 500/600V, you can use VFAS1-6022PL to VFAS1-6110PL.