Toshiba VF-AS1 Power Supply User Manual


 
K-17
E6581528
11
[19] Torque control [2/2] Sensorless vector/vector with sensor (:Effective, -:Ineffective)
Default setting
Vector control
Title
Commun
ication
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)

=
500V
-50Hz

=
575V
-60Hz

=
690V
-50Hz
Write
during
running
Speed
control
Torque
control
V/f
Constant
Reference
 0425
Forward speed limit input
selection
0:Disabled
1:VI/II (voltage/current input)
2:RR/S4 (potentiometer/voltage input)
3:RX (voltage input)
4: enabled
1/1 0 0 0 Enabled - / - *1
 0426 Forward speed limit input level 0.0~ Hz 0.1/0.01
50.0 60.0 50.0
Enabled - / - *1
 0427
Reverse speed limit input
selection
0:Disabled
1:VI/II (voltage/current input)
2:RR/S4 (potentiometer/voltage input)
3:RX (voltage input)
4: enabled
1/1 0 0 0 Enabled - / - *1
 0428 Reverse speed limit input level 0.0~ Hz 0.1/0.01
50.0 60.0 50.0
Enabled - / - *1
 0430
Speed limit (torque = 0) center
value reference selection
0:Disabled
1:VI/II (voltage/current input)
2:RR/S4 (potentiometer/voltage input)
3:RX (voltage input)
4: enabled
1/1 0 0 0 Enabled - / - *1
 0431
Speed limit (torque = 0) center
value
0.0~ Hz 0.1/0.01 0.0 0.0 0.0 Enabled - / - *1
 0432 Speed limit (torque = 0) band 0.0~ Hz 0.1/0.01 0.0 0.0 0.0 Enabled - / - *1
 0435
Prohibition of rotation in any
direction other than the
specified one (F or R)
0:Disabled
1:Enabled
1/1 0 0 0 Enabled - / - *1
*1: For details, refer to Instruction Manual (E6581331) specified in Section 6.42.
[20] Torque limit [1/2] Sensorless vector/vector with sensor (:Effective, -:Ineffective)
Default setting
Vector control
Title
Commun
ication
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)

=
500V
-50Hz

=
575V
-60Hz

=
690V
-50Hz
Write
during
running
Speed
control
Torque
control
V/f
Constant
Reference
 0440
Power running torque limit 1
selection
1:VI/II (voltage/current input)
2:RR/S4 (potentiometer/voltage input)
3:RX (voltage input)
4:
1/1 4 4 4 Enabled / / - 6. 25. 1
 0441
Power running torque limit 1
level
0.0~249.9%, 250.0:Disabled 0.1/0.01 250.0 250.0 250.0 Enabled / / - 6. 25. 1
 0442
Regenerative braking torque
limit 1 selection
1:VI/II (voltage/current input)
2:RR/S4 (potentiometer/voltage input)
3:RX (voltage input)
4:
1/1 4 4 4 Enabled / / - 6. 25. 1