[29] My function [4/5] Sensorless vector/vector with sensor (:Effective, -:Ineffective)
Default setting
Vector control
Title
Communi
cation
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)

=
500V
-50Hz

=
575V
-60Hz

=
690V
-50Hz
Write
during
running
Speed
control
Torque
control
V/f
Constant
Reference
 0948 Input function command 62 Same as  1/1 0 0 0 Enabled / / *1
 0949 Input function target 62 Same as  1/1 0 0 0 Enabled / / *1
 0950 Input function command 63 Same as  1/1 0 0 0 Enabled / / *1
 0951 Input function target 63 Same as  1/1 0 0 0 Enabled / / *1
 0952
Output function assigned
object 6
Same as  1/1 0 0 0 Enabled / / *1
 0953 Input function target 71 Same as  1/1 0 0 0 Enabled / / *1
 0954 Input function command 72 Same as  1/1 0 0 0 Enabled / / *1
 0955 Input function target 72 Same as  1/1 0 0 0 Enabled / / *1
 0956 Input function command 73 Same as  1/1 0 0 0 Enabled / / *1
 0957 Input function target 73 Same as  1/1 0 0 0 Enabled / / *1
 0958
Output function assigned
object 7
Same as  1/1 0 0 0 Enabled / / *1
 0959 Analog input function target 11
0:Disabled
1:VI/II
2:RR/S4
3:RX
4:Optional AI1+, Optional AI1-
5:Optional AI2
1/1 0 0 0 Enabled / / *1
 0961
Analog function assigned
object 11
0:Disabled
1: Acceleration
2: Upper limit frequency ()
3:Acceleration multiplication factor
4:Deceleration multiplication factor
5: Manual torque boost ()
6:OC stall ()
7:Thermal protection ()
8:Speed loop P gain ()
9:Drooping gain ()
10:PID P gain ()
1/1 0 0 0 Disabled / / *1
*1: For details, refer to Instruction Manual (E6581335) specified in Section 6.42.