K-11
E6581528
11
[10] Jump frequency Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Default setting
Vector control
Title
Communi
cation
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
=
500V
-50Hz
=
575V
-60Hz
=
690V
-50Hz
Write
during
running
Speed
control
Torque
control
V/f
Constant
Reference
0270 Jump frequency 1 0.0~ Hz 0.1/0.01 0.0 0.0 0.0 Enabled ●/● - ● 6. 12
0271 Jumping width 1 0.0~30.0Hz 0.1/0.01 0.0 0.0 0.0 Enabled ●/● - ● 6. 12
0272 Jump frequency 2 0.0~ Hz 0.1/0.01 0.0 0.0 0.0 Enabled ●/● - ● 6. 12
0273 Jumping width 2 0.0~30.0Hz 0.1/0.01 0.0 0.0 0.0 Enabled ●/● - ● 6. 12
0274 Jump frequency 3 0.0~ Hz 0.1/0.01 0.0 0.0 0.0 Enabled ●/● - ● 6. 12
0275 Jumping width 3 0.0~30.0Hz 0.1/0.01 0.0 0.0 0.0 Enabled ●/● - ● 6. 12
[11] Preset speed operation frequency (8~15) Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Default setting
Vector control
Title
Communi
cation
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
=
500V
-50Hz
=
575V
-60Hz
=
690V
-50Hz
Write
during
running
Speed
control
Torque
control
V/f
Constant
Reference
0287
Preset speed operation
frequency 8
~ Hz 0.1/0.01 0.0 0.0 0.0 Enabled ●/● - ● 5. 12
0288
Preset speed operation
frequency 9
~ Hz 0.1/0.01 0.0 0.0 0.0 Enabled ●/● - ● 5. 12
0289
Preset speed operation
frequency 10
~ Hz 0.1/0.01 0.0 0.0 0.0 Enabled ●/● - ● 5. 12
0290
Preset speed operation
frequency 11
~ Hz 0.1/0.01 0.0 0.0 0.0 Enabled ●/● - ● 5. 12
0291
Preset speed operation
frequency 12
~ Hz 0.1/0.01 0.0 0.0 0.0 Enabled ●/● - ● 5. 12
0292
Preset speed operation
frequency 13
~ Hz 0.1/0.01 0.0 0.0 0.0 Enabled ●/● - ● 5. 12
0293
Preset speed operation
frequency 14
~ Hz 0.1/0.01 0.0 0.0 0.0 Enabled ●/● - ● 5. 12
0294
Preset speed operation
frequency 15
(Forced operation frequency)
~ Hz 0.1/0.01 0.0 0.0 0.0 Enabled ●/● - ● 5. 12
[12] Tripless intensification setup [1/2] Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Default setting
Vector control
Title
Communi
cation
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
=
500V
-50Hz
=
575V
-60Hz
=
690V
-50Hz
Write
during
running
Speed
control
Torque
control
V/f
Constant
Reference
0300 PWM carrier frequency 1.0~16.0kHz (2.5~8.0kHz) *1 0.1/0.1 *2 *2 *2 Enabled ●/● ●/● ● 5. 17
0301 Auto-restart control selection
0:Disabled, 1:At auto-restart
2:When turning ST operation standby signal on
or off, 3:1+2, 4:Starting
1/1 0 0 0 Disabled ●/● ●/● ● 5. 18.1
0302
Regenerative power
ride-through control
0:Disabled, 1:Power ride-through
2:Deceleration stop during power failure
3:Synchronized deceleration/acceleration
(synchronized acceleration/deceleration
signal)
4:Synchronized deceleration/acceleration
(synchronized acceleration/deceleration signal+power
failure)
1/1 0 0 0 Disabled ●/● -/- ● 5. 18. 2
0303 Retry selection 0:Deselect, 1-10 times 1/1 0 0 0 Enabled ●/● ●/● ● 6. 14. 1