Toshiba VF-AS1 Power Supply User Manual


 
K-41
E6581528
11
[Input terminal function setting (1/2)] Sensorless vector/vector with sensor (: valid, -: invalid)
Positive
logic
Negative
logic
Function
Speed
control
Tor qu e
control
V/f = = Reference
0 1 No function is assigned / / - -
2 3 F: Forward run command / / -
4 5 R: Reverse run command / / -
6 7 ST: Standby / / *1 -
8 9 RES: Reset / / *2 -
10 11 S1: Preset speed 1 / - -
12 13 S2: Preset speed 2 / - -
14 15 S3: Preset speed 3 / - -
16 17 S4: Preset speed 4 / - -
18 19 Jog run / -
20 21 Emergency stop / / *2 -
22 23 DC braking / -
24 25 Acceleration/deceleration switching 1 / - -
26 27 Acceleration/deceleration switching 2 / - -
28 29 V/f switching signal 1 / - -
30 31 V/f switching signal 2 / - -
32 33 Torque limit switching signal 1 / / -
34 35 Torque limit switching signal 2 / / -
36 37 PID control OFF selection / - -
38 39 Pattern operation selection 1 / - -
40 41 Pattern operation selection 2 / - -
42 43 Pattern operation continuation signal / - -
44 45 Pattern operation trigger signal / - -
46 47 External thermal error / - -
48 49 Communication priority cancel / - -
50 51
Holding of HD operation (stop of three-wire
operation)
/ - -
52 53 PID differentiation/integration reset / - -
54 55 PID forward/reverse switching / - -
56 57 Forced continuous operation / - -
58 59 Specified speed operation / - -
60 61 Acceleration/deceleration suspend signal / - -
62 63 Power failure synchronized signal / - -
64 65 My function RUN signal / / -
66 67 Auto-tuning signal / - -
68 69 Speed gain switching / - -
7.2.1
*1: Valid any time
*2: Independent of , and all command are valid.