K-19
E6581528
11
[21] Adjustment parameters [2/2] Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Default setting
Vector control
Title
Commun
ication
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
=
500V
-50Hz
=
575V
-60Hz
=
690V
-50Hz
Write
during
running
Speed
control
Torque
control
V/f
Constant
Reference
0475 RX input gain 0~255 1/1 *1 *1 *1 Enabled ●/● ●/● ● 6. 28
0476 Optional AI1 input bias 0~255 1/1 *1 *1 *1 Enabled ●/● ●/● ● 6. 28
0477 Optional AI1 input gain 0~255 1/1 *1 *1 *1 Enabled ●/● ●/● ● 6. 28
0478 Optional AI2 input bias 0~255 1/1 *1 *1 *1 Enabled ●/● ●/● ● 6. 28
0479 Optional AI2 input gain 0~255 1/1 *1 *1 *1 Enabled ●/● ●/● ● 6. 28
0495
Max output voltage modulation
rate
0:Standard
1:Straight 100%
2:102.5%
3:105%
1/1 0 0 0 Disabled ●/● ●/● ● -
0498
PM motor constant 1 (d axis
inductance)
0~25% 0.1/0.1 10.0 10.0 10.0 Disabled - - - 6. 29
0499
PM motor constant 2 (q axis
inductance)
0~25% 0.1/0.1 10.0 10.0 10.0 Disabled - - - 6. 29
*1: ⇒ Settings vary from unit to unit. Even if is set to , no change is made to these values.
[22] Acceleration/deceleration 2 [1/2] Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Default setting
Vector control
Title
Commun
ication
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
=
500V
-50Hz
=
575V
-60Hz
=
690V
-50Hz
Write
during
running
Speed
control
Torque
control
V/f
Constant
Reference
0500 Acceleration time 2 0.1~6000 sec. 0.1/0.1 *2 *1 *1 *1 Enabled ●/● - ● 6. 30. 1
0501 Deceleration time 2 0.1~6000 sec. 0.1/0.1 *2 *1 *1 *1 Enabled ●/● - ● 6. 30. 1
0502
Acceleration/deceleration 1
pattern
0:Straight, 1:S-pattern 1, 2:S-pattern 2 1/1 0 0 0 Enabled ●/● - ● 6. 30. 1
0503
Acceleration/deceleration 2
pattern
0:Straight, 1:S-pattern 1, 2:S-pattern 2 1/1 0 0 0 Enabled ●/● - ● 6. 30. 1
0504
Panel
acceleration/deceleration
selection
1:Acceleration/deceleration 1
2:Acceleration/deceleration 2
3:Acceleration/deceleration 3
4:Acceleration/deceleration 4
1/1 1 1 1 Enabled ●/● - ● 6. 30. 1
0505
Acceleration/deceleration
switching frequency 1
0.0~ Hz 0. 1/0.01 0.0 0.0 0.0 Enabled ●/● - ● 6. 30. 1
0506
Acceleration S-pattern lower
limit adjustment
0~50% 1/1 10 10 10 Enabled ●/● - ● 6. 30. 1
0507
Acceleration S-pattern upper
limit adjustment
0~50% 1/1 10 10 10 Enabled ●/● - ● 6. 30. 1
0508
Deceleration S-pattern lower
limit adjustment
0~50% 1/1 10 10 10 Enabled ●/● - ● 6. 30. 1
0509
Deceleration S-pattern upper
limit adjustment
0~50% 1/1 10 10 10 Enabled ●/● - ● 6. 30. 1
0510 Acceleration time 3 0.1~6000 sec. 0.1/0.1 *2 *1 *1 *1 Enabled ●/● - ● 6. 30. 1
0511 Deceleration time 3 0.1~6000 sec. 0.1/0.1 *2 *1 *1 *1 Enabled ●/● - ● 6. 30. 1
0512
Acceleration/ deceleration 3
pattern
0:Straight, 1:S-pattern 1, 2:S-pattern 2 1/1 0 0 0 Enabled ●/● - ● 6. 30. 1
0513
Acceleration/deceleration
switching frequency 2
0.0~ Hz 0.1/0.01 0.0 0.0 0.0 Enabled ●/● - ● 6. 30. 1
*1: Default values vary depending on the capacity. ⇒ See the table of K-46.
*2: Changing the parameter enables to set to 0.01 sec. (adjustment range: 0.01~600.0 sec.).