[22] Acceleration/deceleration 2 [2/2] Sensorless vector/vector with sensor (:Effective, -:Ineffective)
Default setting
Vector control
Title
Commun
ication
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)

=
500V
-50Hz

=
575V
-60Hz

=
690V
-50Hz
Write
during
running
Speed
control
Torque
control
V/f
Constant
Reference
 0514 Acceleration time 4 0.1~6000 sec. 0.1/0.1 *2 *1 *1 *1 Enabled / - 6. 30. 1
 0515 Deceleration time 4 0.1~6000 sec. 0.1/0.1 *2 *1 *1 *1 Enabled / - 6. 30. 1
 0516
Acceleration/ deceleration 4
pattern
0:Straight, 1:S-pattern 1, 2:S-pattern 2 1/1 0 0 0 Enabled / - 6. 30. 1
 0517
Acceleration/deceleration
switching frequency 3
0.0~ Hz 0.1/0.01 0.0 0.0 0.0 Enabled / - 6. 30. 1
*1: Default values vary depending on the capacity. See the table of K-46.
*2: Changing the parameter  enables to set to 0.01 sec. (adjustment range: 0.01~600.0 sec).
[23] Pattern operation [1/3] Sensorless vector/vector with sensor (:Effective, -:Ineffective)
Default setting
Vector control
Title
Commun
ication
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)

=
500V
-50Hz

=
575V
-60Hz

=
690V
-50Hz
Write
during
running
Speed
control
Torque
control
V/f
Constant
Reference
 0520 Pattern operation selection
0:Disabled
1:Enabled (setting in units of seconds)
2:Enabled (setting in units of minutes)
1/1 0 0 0 Disabled / - 6. 31
 0521 Pattern operation mode
0:Pattern operation reset when system stops
operation
1:Pattern operation continued even after
system stops operation
1/1 0 0 0 Disabled / - 6. 31
 0522
Number of repetitions of pattern
group 1
1~254, 255:Successive 1/1 1 1 1 Disabled / - 6. 31
 0523 Pattern group 1 selection 1 0:Skip, 1~15 1/1 0 0 0 Disabled / - 6. 31
 0524 Pattern group 1 selection 2 0:Skip, 1~15 1/1 0 0 0 Disabled / - 6. 31
 0525 Pattern group 1 selection 3 0:Skip, 1~15 1/1 0 0 0 Disabled / - 6. 31
 0526 Pattern group 1 selection 4 0:Skip, 1~15 1/1 0 0 0 Disabled / - 6. 31
 0527 Pattern group 1 selection 5 0:Skip, 1~15 1/1 0 0 0 Disabled / - 6. 31
 0528 Pattern group 1 selection 6 0:Skip, 1~15 1/1 0 0 0 Disabled / - 6. 31
 0529 Pattern group 1 selection 7 0:Skip, 1~15 1/1 0 0 0 Disabled / - 6. 31
 0530 Pattern group 1 selection 8 0:Skip, 1~15 1/1 0 0 0 Disabled / - 6. 31
 0531
Number of repetitions of pattern
group 2
1~254, 255:Successive 1/1 1 1 1 Disabled / - 6. 31
 0532 Pattern group 2 selection 1 0:Skip, 1~15 1/1 0 0 0 Disabled / - 6. 31
 0533 Pattern group 2 selection 2 0:Skip, 1~15 1/1 0 0 0 Disabled / - 6. 31
 0534 Pattern group 2 selection 3 0:Skip, 1~15 1/1 0 0 0 Disabled / - 6. 31
 0535 Pattern group 2 selection 4 0:Skip, 1~15 1/1 0 0 0 Disabled / - 6. 31
 0536 Pattern group 2 selection 5 0:Skip, 1~15 1/1 0 0 0 Disabled / - 6. 31
 0537 Pattern group 2 selection 6 0:Skip, 1~15 1/1 0 0 0 Disabled / - 6. 31
 0538 Pattern group 2 selection 7 0:Skip, 1~15 1/1 0 0 0 Disabled / - 6. 31
 0539 Pattern group 2 selection 8 0:Skip, 1~15 1/1 0 0 0 Disabled / - 6. 31
 0540 Speed 1 operation time
0.1~6000 (The unit depends on the setting of
.)
6000:Infinite (depends on the stop trigger
entered)
0.1/0.1 5.0 5.0 5.0 Enabled / - 6. 31
 0541 Speed 2 operation time Ditto 0.1/0.1 5.0 5.0 5.0 Enabled / - 6. 31