[29] My function [5/5] Sensorless vector/vector with sensor (:Effective, -:Ineffective)
Default setting
Vector control
Title
Communi
cation
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)

=
500V
-50Hz

=
575V
-60Hz

=
690V
-50Hz
Write
during
running
Speed
control
Torque
control
V/f
Constant
Reference
 0962 Analog input function target 21
0:Disabled
1:VI/II
2:RR/S4
3:RX
4:Optional AI1+, Optional AI1-
5:Optional AI2
1/1 0 0 0 Enabled / / *1
 0964
Analog function assigned object
21
0~10 1/1 0 0 0 Disabled / / *1
 0965 Monitor output function target 11
2000~2099:FD00~FD99
3000~3099:FE00~FE99
1/1 2000 2000 2000 Enabled / / *1
 0966
Monitor output function
command 11
0:Normal monitor, 1:Max. value, 2:Min. value 1/1 0 0 0 Enabled / / *1
 0967
Monitor output function target
21
2000~2099:FD00~FD99
3000~3099:FE00~FE99
1/1 2000 2000 2000 Enabled / / *1
 0968
Monitor output function
command 21
0:Normal monitor, 1:Max. value, 2:Min. value 1/1 0 0 0 Enabled / / *1
 0969
Monitor output function target
31
2000~2099:FD00~FD99
3000~3099:FE00~FE99
1/1 2000 2000 2000 Enabled / / *1
 0970
Monitor output function
command 31
0:Normal monitor, 1:Max. value, 2:Min. value 1/1 0 0 0 Enabled / / *1
 0971
Monitor output function target
41
2000~2099:FD00~FD99
3000~3099:FE00~FE99
1/1 2000 2000 2000 Enabled / / *1
 0972
Monitor output function
command 41
0:Normal monitor, 1:Max. value, 2:Min. value 1/1 0 0 0 Enabled / / *1
 0973 Virtual input terminal selection 1 0~135 *2 1/1 0 0 0 Disabled / / *1
 0974 Virtual input terminal selection 2 0~135 *2 1/1 0 0 0 Disabled / / *1
 0975 Virtual input terminal selection 3 0~135 *2 1/1 0 0 0 Disabled / / *1
 0976 Virtual input terminal selection 4 0~135 *2 1/1 0 0 0 Disabled / / *1
 0977 My function selection
0:Disabled
1:My function + permission signal
2:My function always ON
1/1 0 0 0 Disabled / / *1
*1: For details, refer to Instruction Manual (E6581335) specified in Section 6.42. *2: For the adjustment range, see the table on page K-41.
[30] Travenirse function Sensorless vector/vector with sensor (:Effective, -:Ineffective)
Default setting
Vector control
Title
Commun
ication
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)

=
500V
-50Hz

=
575V
-60Hz

=
690V
-50Hz
Write
during
running
Speed
control
Torque
control
V/f
Constant
Reference
 0980 Traverse selection
0:Disabled
1:Enabled
1/1 0 0 0 Disabled / - *1
 0981 Traverse acceleration time 0.1~120.0 sec. 0.1/0.1 25.0 25.0 25.0 Enabled / - *1
 0982 Traverse deceleration time 0.1~120.0 sec. 0.1/0.1 25.0 25.0 25.0 Enabled / - *1
 0983 Traverse step 0.0~25.0% 0.1/0.1 10.0 10.0 10.0 Enabled / - *1
 0984 Traverse jump step 0.0~50.0% 0.1/0.1 10.0 10.0 10.0 Enabled / - *1
*1: For details, refer to Instruction Manual (E6581337) specified in Section 6.42.