K-25
E6581528
11
[26] Meter output Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Default setting
Vector control
Title
Communi
cation
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
=
500V
-50Hz
=
575V
-60Hz
=
690V
-50Hz
Write
during
running
Speed
control
Torque
control
V/f
Constant
Reference
0671 AM terminal meter adjustment - 1/1 - - - Enabled ●/● ●/● ● 5. 16
0672
MON1 terminal meter
selection
0~64 *1 1/1 4 4 4 Enabled ●/● ●/● ● *2
0673
MON1 terminal meter
adjustment
- 1/1 - - - Enabled ●/● ●/● ● *2
0674
MON2 terminal meter
selection
0~64 *1 1/1 5 5 5 Enabled ●/● ●/● ● *2
0675
MON2 terminal meter
adjustment
- 1/1 - - - Enabled ●/● ●/● ● *2
0676 Pulse output function selection 0~49 *1 1/1 0 0 0 Enabled ●/● ●/● ● 6. 35. 1
0677 Selection of number of pulses 1.00~43.20kHz 0.01/0.01 3.84 3.84 3.84 Enabled ●/● ●/● ● 6. 35. 1
0678 Constant at the time of filtering 4msec, 8msec~100msec 1/1 64 64 64 Enabled ●/● ●/● ● 5. 16
0681
FM voltage/current output
switching
0:Voltage 0~10V output
1:Current 0~20mA output
1/1 0 0 0 Disabled ●/● ●/● ● 6. 35. 3
0682
FM output gradient
characteristic
0:Negative gradient (descending)
1:Positive gradient (ascending)
1/1 1 1 1 Enabled ●/● ●/● ● 6. 35. 3
0683 FM bias adjustment -10.0~100.0% 0.1/0.1 0.0 0.0 0.0 Enabled ●/● ●/● ● 6. 35. 3
0684 FM output filter
0:No filter
1:Filter approx. 10ms
2:Filter approx. 15ms
3:Filter approx. 30ms
4:Filter approx. 60ms
5:Filter approx. 120ms
6:Filter approx. 250ms
7:Filter approx. 500ms
8:Filter approx. 1s
1/1 0 0 0 Enabled ●/● ●/● ● 5. 16
0685
AM output gradient
characteristic
0:Negative inclination (downward slope)
1:Positive inclination (upward slope)
1/1 1 1 1 Enabled ●/● ●/● ● 6. 35. 3
0686 AM bias adjustment -10.0~100.0% 0.1/0.1 0.0 0.0 0.0 Enabled ●/● ●/● ● 6. 35. 3
0688
MON1 voltage/current output
switching
0:Voltage -10~10V output
1:Voltage 0~10V output
2:Current 0~20mA output
1/1 1 1 1 Disabled ●/● ●/● ● *2
0689
MON1 output gradient
characteristic
0:Negative inclination (downward slope)
1:Positive inclination (upward slope)
1/1 1 1 1 Enabled ●/● ●/● ● *2
0690 MON1 bias adjustment -10.0~100.0% 0.1/0.1 0.0 0.0 0.0 Enabled ●/● ●/● ● *2
0691
MON2 voltage/current output
switching
0:Voltage -10~10V output
1:Voltage 0~10V output
2:Current 0~20mA output
1/1 1 1 1 Disabled ●/● ●/● ● *2
0692
MON2 output gradient
characteristic
0:Negative inclination (downward slope)
1:Positive inclination (upward slope)
1/1 1 1 1 Enabled ●/● ●/● ● *2
0693 MON2 bias adjustment -10.0~100.0% 0.1/0.1 0.0 0.0 0.0 Enabled ●/● ●/● ● *2
This parameter moves to a fundamental parameter.
*1: ⇒ For the adjustment range, see the table on page K-39.
*2: ⇒ For details, refer to Instruction Manual (E6581341) specified in Section 6.42.