[6] Speed/torque reference gain/bias setup [2/2] Sensorless vector/vector with sensor (:Effective, -:Ineffective)
Default setting
Vector control
Title
Commun
ication
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)

=
500V
-50Hz

=
575V
-60Hz

=
690V
-50Hz
Write
during
running
Speed
control
Torque
control
V/f
Constant
Reference
 0212 RR/S4 input point 2 setting 0~100% 1/1 100 100 100 Enabled / / 7. 3. 1
 0213 RR/S4 input point 2 frequency 0.0~ Hz 0.1/0.01 50.0 60.0 50.0 Enabled / - 5. 11
 0214 RR/S4 input point 1 rate 0~250% (for torque control etc.) 1/0.01 0 0 0 Enabled / / - *1
 0215 RR/S4 input point 2 rate 0~250% (for torque control etc.) 1/0.01 100 100 100 Enabled / / - *1
 0216 RX input point 1 setting -100~100% 1/1 0 0 0 Enabled / / 7. 3. 3
 0217 RX input point 1 frequency 0.0~ Hz 0.1/0.01 0.0 0.0 0.0 Enabled / - 7. 3. 3
 0218 RX input point 2 setting -100~100% 1/1 100 100 100 Enabled / / 7. 3. 3
 0219 RX input point 2 frequency 0.0~ Hz 0.1/0.01 50.0 60.0 50.0 Enabled / - 7. 3. 3
 0220 RX input point 1 rate -250~250% (for torque control etc.) 1/0.01 0 0 0 Enabled / / - *1
 0221 RX input point 2 rate -250~250% (for torque control etc.) 1/0.01 100 100 100 Enabled / / - *1
 0222 AI1 input point 1 setting -100~100% 1/1 0 0 0 Enabled / / *2
 0223 AI1 input point 1 frequency 0.0~ Hz 0.1/0.01 0.0 0.0 0.0 Enabled / - *2
 0224 AI1 input point 2 setting -100-100% 1/1 100 100 100 Enabled / / *2
 0225 AI1 input point 2 frequency 0.0~ Hz 0.1/0.01 50.0 60.0 50.0 Enabled / - *2
 0226 AI1 input point 1 rate -250~250% (for torque control etc.) 1/0.01 0 0 0 Enabled / / - *2
 0227 AI1 input point 2 rate -250~250% (for torque control etc.)
1/
0.01
100 100 100 Enabled / / - *2
 0228 AI2 input point 1 setting 0~100% 1/1 0 0 0 Enabled / / *2
 0229 AI2 input point 1 frequency 0.0~ Hz 0.1/0.01 0.0 0.0 0.0 Enabled / - *2
 0230 AI2 input point 2 setting 0~100% 1/1 100 100 100 Enabled / / *2
 0231 AI2 input point 2 frequency 0.0~ Hz 0.1/0.01 50.0 60.0 50.0 Enabled / - *2
 0234
RP/high speed pulse input
point 1 setting
0~100% 1/1 0 0 0 Enabled / - *3
 0235
RP/high speed pulse input
point 1 frequency
0.0~ Hz 0.1/0.01 0.0 0.0 0.0 Enabled / - *3
 0236
RP/high speed pulse input
point 2 setting
0~100% 1/1 100 100 100 Enabled / - *3
 0237
RP/high speed pulse input
point 2 frequency
0.0~ Hz 0.1/0.01 50.0 60.0 50.0 Enabled / - *3
This parameter moves to a fundamental parameter.
*1: For details, refer to Instruction Manual (E6581331) specified in Section 6.42.
*2: For details, refer to Instruction Manual (E6581341) specified in Section 6.42.
*3: For details, refer to Instruction Manual (E6581319) specified in Section 6.42.