Toshiba VF-AS1 Power Supply User Manual


 
K-44
E6581528
11
[Output terminal function setting (2/3)] Sensorless vector/vector with sensor (: valid, -: invalid)
Positive
logic
Negative
logic
Function Speed control Torque control V/f Reference
76 77 Inverter healthy output
/ /
78 79 RS485 communication error
/ /
80 81 Error code output 1 (6-bit output)
/ /
82 83 Error code output 2 (6-bit output)
/ /
84 85 Error code output 3 (6-bit output)
/ /
86 87 Error code output 4 (6-bit output)
/ /
88 89 Error code output 5 (6-bit output)
/ /
90 91 Error code output 6 (6-bit output)
/ /
92 93 Designated data output 1 (7-bit output)
/ /
94 95 Designated data output 2 (7-bit output)
/ /
96 97 Designated data output 3 (7-bit output)
/ /
98 99 Designated data output 4 (7-bit output)
/ /
100 101 Designated data output 5 (7-bit output)
/ /
102 103 Designated data output 6 (7-bit output)
/ /
104 105 Designated data output 7 (7-bit output)
/ /
106 107 Light load signal
/
-/-
108 109 Heavy load signal
/
-/-
110 111 Positive torque limit
/ /
112 113 Negative torque limit
/ /
114 115 Output for external rush suppression relay
/ /
118 119
Completion of stop positioning (for simple positioning)
-/- -/- -
120 121
L-STOP
/ /
122 123
Power failure synchronized operation
/ /
124 125
Traverse motion
/ /
126 127
Traverse deceleration in progress
/ /
128 129
Part replacement alarm
/ /
130 131
Overtorque pre-alarm
/ /
132 133
Operation frequency command
1
/
2
selection
/ /
134 135
Failure FL (except emergency stop)
/ /
222 223
My function output
1
/ /
224 225
My function output
2
/ /
226 227
My function output
3
/ /
228 229
My function output
4
/ /
230 231
My function output
5
/ /
232 233
My function output
6
/ /
234 235
My function output
7
/ /
236 237
My function output
8
/ /
238 239
My function output
9
/ /
7.2.2