E6581528
11
K-8
[5] V/f 5-point setting Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Default setting
Vector control
Title
Commun
ication
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
=
500V
-50Hz
=
575V
-60Hz
=
690V
-50Hz
Write
during
running
Speed
control
Torque
control
V/f
Constant
Reference
0190
V/f 5-point setting VF1
frequency
0.0~ Hz 0.1/0.01 0.0 0.0 0.0 Disabled - - ● 5. 6
0191 V/f 5-point setting VF1 voltage 0.0~100.0% 0.1/0.01 0.0 0.0 0.0 Disabled - - ● 5. 6
0192
V/f 5-point setting VF2
frequency
0.0~ Hz 0.1/0.01 0.0 0.0 0.0 Disabled - - ● 5. 6
0193 V/f 5-point setting VF2 voltage 0.0~100.0% 0.1/0.01 0.0 0.0 0.0 Disabled - - ● 5. 6
0194
V/f 5-point setting VF3
frequency
0.0~ Hz 0.1/0.01 0.0 0.0 0.0 Disabled - - ● 5. 6
0195 V/f 5-point setting VF3 voltage 0.0~100.0% 0.1/0.01 0.0 0.0 0.0 Disabled - - ● 5. 6
0196
V/f 5-point setting VF4
frequency
0.0~ Hz 0.1/0.01 0.0 0.0 0.0 Disabled - - ● 5. 6
0197 V/f 5-point setting VF4 voltage 0.0~100.0% 0.1/0.01 0.0 0.0 0.0 Disabled - - ● 5. 6
0198
V/f 5-point setting VF5
frequency
0.0~ Hz 0.1/0.01 0.0 0.0 0.0 Disabled - - ● 5. 6
0199 V/f 5-point setting VF5 voltage 0.0~100.0% 0.1/0.01 0.0 0.0 0.0 Disabled - - ● 5. 6
[6] Speed/torque reference gain/bias setup [1/2] Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Default setting
Vector control
Title
Commun
ication
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
=
500V
-50Hz
=
575V
-60Hz
=
690V
-50Hz
Write
during
running
Speed
control
Torque
control
V/f
Constant
Reference
0200 Frequency priority selection
0:/ terminal switching (input
terminal function selection 104, 105)
1:/ frequency switching
(switching with )
1/1 0 0 0 Enabled ●/● - ● 6. 6. 1
0201 VI/II input point 1 setting 0~100% 1/1 0 0 0 Enabled ●/● ●/● ● 7. 3. 2
0202 VI/II input point 1 frequency 0.0~ Hz 0.1/0.01 0.0 0.0 0.0 Enabled ●/● - ● 7. 3. 2
0203 VI/II input point 2 setting 0~100% 1/1 100 100 100 Enabled ●/● ●/● ● 7. 3. 2
0204 VI/II input point 2 frequency 0.0~ Hz 0.1/0.01 50.0 60.0 50.0 Enabled ●/● - ● 5. 11
0205 VI/II input point 1 rate 0~250% (for torque control etc.) 1/0.01 0 0 0 Enabled ●/● ●/● - *1
0206 VI/II input point 2 rate 0~250% (for torque control etc.) 1/0.01 100 100 100 Enabled ●/● ●/● - *1
0207
Frequency setting mode
selection 2
Same as (1~13) 1/1 1 1 1 Disabled ●/● - ● 6. 6. 1
0208
Speed command priority
switching frequency
0.1~ Hz 0.1/0.01 0.1 0.1 0.1 Enabled ●/● - ● 6. 6. 1
0209 Analog input filter
0:No filter
1:Filter approx. 10ms
2:Filter approx. 15ms
3:Filter approx. 30ms
4:Filter approx. 60ms
1/1 0 0 0 Enabled ●/● ●/● ● 7. 2. 4
0210 RR/S4 input point 1 setting 0~100% 1/1 0 0 0 Enabled ●/● ●/● ● 7. 3. 1
0211 RR/S4 input point 1 frequency 0.0~ Hz 0.1/0.01 0.0 0.0 0.0 Enabled ●/● - ● 7. 3. 1
This parameter moves to a fundamental parameter.
*1 ⇒ For details, refer to Instruction Manual (E6581331) specified in Section 6.42.