[27] Operation panel parameters [2/3] Sensorless vector/vector with sensor (:Effective, -:Ineffective)
Default setting
Vector control
Title
Communi
cation
No.
Function Adjustment range
Minimum
setting unit
(Panel/Communi
cation)

=
500V
-50Hz

=
575V
-60Hz

=
690V
-50Hz
Write
during
running
Speed
control
Torque
control
V/f
Constant
Reference
 0734
Operation panel emergency
stop operation prohibition
selection
0:Permit
1:Prohibit
1/1 0 0 0 Enabled / / 6. 36. 1
 0735
Operation panel reset
operation prohibition selection
0:Permit
1:Prohibit
1/1 0 0 0 Enabled / / 6. 36. 1
 0736
Prohibition of change of
/ during
operation
0:Permit
1:Prohibit
1/1 1 1 1 Enabled / / 6. 36. 1
 0737 All key operation prohibition
0:Permit
1:Prohibit
1/1 0 0 0 Enabled / / 6. 36. 1
 0740 Trace selection 0:Deselect, 1:At tripping, 2:At triggering 1/1 1 1 1 Enabled / / 6. 37
 0741 Trace cycle 0:4ms, 1:20ms, 2:100ms, 3:1s, 4:10s 1/1 2 2 2 Enabled / / 6. 37
 0742 Trace data 1 0~49 1/1 0 0 0 Enabled / / 6. 37
 0743 Trace data 2 0~49 1/1 1 1 1 Enabled / / 6. 37
 0744 Trace data 3 0~49 1/1 2 2 2 Enabled / / 6. 37
 0745 Trace data 4 0~49 1/1 3 3 3 Enabled / / 6. 37
 0748
Integral output power retention
selection
0:Disabled
1:Enabled
1/1 1 1 1 Enabled / / 6. 38
 0749
Integral output power display
unit selection
0:1=1kWh
1: 0.1=1kWh
2: 0.01=1kWh
3: 0.001=1kWh
4: 0.0001=1kWh
1/1 *2 *2 *2 Enabled / / 6. 38
 0750 EASY key function selection
0:Quick mode/standard setting mode switching
function
1:
Shortcut key
:Pressing for 2 sec. to record the
parameter, pressing normally to
jump to recorded parameter (first
jump to the 1st history)
2:Operation panel/remote key:Operation panel
by ON
3:Monitor peak minimum hold trigger
1/1 0 0 0 Disabled / / 5. 22
 0751 Quick registration parameter 1 0~999 *1 1/1
40
(AU4)
40
(AU4)
40
(AU4)
Enabled / / 5. 22
 0752 Quick registration parameter 2 0~999 *1 1/1
15
(pt)
15
(pt)
15
(pt)
Enabled / / 5. 22
 0753 Quick registration parameter 3 0~999 *1 1/1
11
(FH)
11
(FH)
11
(FH)
Enabled / / 5. 22
 0754 Quick registration parameter 4 0~999 *1 1/1
9
(ACC)
9
(ACC)
9
(ACC)
Enabled / / 5. 22
 0755 Quick registration parameter 5 0~999 *1 1/1
10
(dEC)
10
(dEC)
10
(dEC)
Enabled / / 5. 22
 0756 Quick registration parameter 6 0~999 *1 1/1
600
(tHr)
600
(tHr)
600
(tHr)
Enabled / / 5. 22
*1: The communication number of the parameter is used for this setting.