Toshiba VF-AS1 Power Supply User Manual


 
K-39
E6581528
11
[Monitor FM/AM/pulse output function selection (1/2)] Sensorless vector/vector with sensor : valid, -: invalid)
FM/AM/pulse output
Monitor output
Option No.
Communicati
on No.
Option No.
Communicati
on No.
Function
Unit
(Communicat
ion)
Trip retention
Speed
control
Torque
control
V/f Reference
0 FD00 0 FE00 Output frequency 0.01Hz / /
1 FD02 1 FE02 Frequency command value 0.01Hz
/ -
2 FD03 2 FE03 Output current 0.01%
/ /
3 FD04 3 FE04 Input voltage (DC detection) 0.01%
/ /
4 FD05 4 FE05 Output voltage 0.01%
/ /
5 FD15 5 FE15 Compensated frequency 0.01Hz
/ /
6 FD16 6 FE16 Speed feedback (real-time value) *1 0.01Hz
-/ -/ -
7 FD17 7 FE17 Speed feedback (1-second filter) *1 0.01Hz
-/ -/ -
8 FD18 8 FE18 Torque 0.01%
/ / *2
9 FD19 9 FE19 Torque command 0.01%
- / -
11 FD20 11 FE20 Torque current 0.01%
/ / *2
12 FD21 12 FE21 Exciting current 0.01%
/ / *2
13 FD22 13 FE22 PID feedback value 0.01Hz
/ -
14 FD23 14 FE23 Motor overload factor (OL2 data) 0.01%
/ /
15 FD24 15 FE24 Inverter overload factor (OL1 data) 0.01%
/ /
16 FD25 16 FE25
Regenerative braking resistance
overload factor (OLr data)
1%
/ /
17 FD28 17 FE28
Regenerative braking resistor load factor (% ED)
1%
/ /
18 FD29 18 FE29 Input power 0.01kW
/ /
19 FD30 19 FE30 Output power 0.01kW
/ /
23 FE39 23 FE39 Optional AI2 input *4 × / /
24 FE35 24 FE35 RR/S4 input *3 × / /
25 FE36 25 FE36 VI/II input *3 × / /
26 FE37 26 FE37 RX input *3 × / /
27 FE38 27 FE38 Optional AI1 input *4 × / /
28 FE40 28 FE40 FM output 1 × / /
29 FE41 29 FE41 AM output 1 × / /
30 FE51 - - Fixed output 1 0.01% × / /
31 FA51 *5 - - Communication data output 1 × / /
32 FE50 - - Fixed output 2 0.01% × / /
33 FE52 - - Fixed output 3 0.01% × / /
- - 31 FA65 Communication data output 0.01% × / /
- - 32 FE66
Attached to expansion I/O card 1 CPU
version
- × / /
5.16
8.3
*1: Estimated speed is output if there is no PG feedback. If used as pulse input command with PG feedback option, frequency is displayed as in the PG feedback.
*2: Reference data *3: Analog value entered: Analog value entered × value monitored/2047 *4:Analog value entered: Analog value entered × value monitored/1023
*5: Communication no. FA51 is used for FM, FA52 for AM, FA53 for MON1 and FA54 for MON2 and pulse output, respectively.
For details, refer to Section 5.16; [Terminal FM-related parameters].
For monitor indications, refer to Section 8.3; [Set up values of monitor indication parameters].