[SENSe:]
VOLTage:DC:RANGe:AUTO? [(
@<ch_list>)]
VOLTage:AC:RANGe:AUTO? [(
@<ch_list>)]
RESistance:RANGe:AUTO? [(
@<ch_list>)]
FRESistance:RANGe:AUTO? [(
@<ch_list>)]
CURRent:DC:RANGe:AUTO? [(@<ch_list>)]
CURRent:AC:RANGe:AUTO? [(
@<ch_list>)]
FREQuency:VOLTage:RANGe:AUTO? [(
@<ch_list>)]
PERiod:VOLTage:RANGe:AUTO? [(
@<ch_list>)]
Query the autorange setting on the specified channels. Returns “0” (
OFF)
or “1” (
ON).
[SENSe:]
VOLTage:DC:RESolution {<
resolution>|MIN|MAX}[,(@<ch_list>)]
RESistance:RESolution {<
resolution>|MIN|MAX}[,(@<ch_list>)]
FRESistance:RESolution {<
resolution>|MIN|MAX}[,(@<ch_list>)]
CURRent:DC:RESolution {<
resolution>|MIN|MAX}[,(@<ch_list>)]
Select the resolution for the function selected on the specified channels.
Specify the resolution in the same units as the measurement function,
not in number of digits.
MIN selects the smallest value accepted for this
parameter, which gives the most resolution.
MAX selects the largest
value accepted for this parameter, which gives the least resolution.
For more information on the relationship between integration time,
measurement resolution, number of digits, and number of bits, see the
table on page 203.
[SENSe:]
VOLTage:DC:RESolution? [{(
@<ch_list>)|MIN|MAX}]
RESistance:RESolution? [{(
@<ch_list>)|MIN|MAX}]
FRESistance:RESolution? [{(
@<ch_list>)|MIN|MAX}]
CURRent:DC:RESolution? [{(
@<ch_list>)|MIN|MAX}]
Query the resolution setting on the specified channels. Returns a
number in the form “+
3.00000000E-05”.
Chapter 5 Remote Interface Reference
Setting the Function, Range, and Resolution
216