Agilent Technologies 34970A Switch User Manual


 
SOUR:DIG:DATA:BYTE command, 258
SOUR:DIG:DATA:WORD command, 258
SOUR:DIG:STATe? command, 258
SOUR:VOLTage command, 258
SCPI language, short form, 297
SPDT (Form C) switching, 59, 384
specifications, 203-220
ac accuracy, 406
BenchLink Data Logger, 412
dc accuracy, 404
plug-in modules, 409
speed, scanning, 405, 407
standard event register
bit definitions, 282
clearing bits, 283
standard operation register
bit definitions, 285
clearing bits, 285
Standby (Power) switch, 17
state storage
definition, 48
front-panel operation, 141
naming states, 48, 140
power-down recall, 140
remote operation, 141
statistics, while scanning, 75
status byte
bit definitions, 277
clearing bits, 277
status register
alarm register, 284
condition register, 275
enable register, 275
example program, 330
event register, 275
questionable data register, 280
register diagram, 276
standard event register, 282
standard operation register, 285
status byte, 277
STATus:ALARm:COND? command, 289
STATus:ALARm:ENABle command, 289
STATus:ALARm:EVENt? command, 289
STATus:OPER:COND? command, 290
STATus:OPER:ENABle command, 290
STATus:OPER:EVENt? command, 290
STATus:PRESet? command, 291
STATus:QUES:COND? command, 287
STATus:QUES:ENABle command, 287
STATus:QUES:EVENt? command, 287
Step key, 24, 78
Sto/Rcl key, 36, 48
stop bits (RS-232), 270
stopping scan, 81
stored states
definition, 48
front-panel operation, 141
naming states, 48, 140
power-down recall, 140
remote operation, 141
strain gage
common uses, 374
gage factor, 374
measurements, 120, 373
Mx+B equations, 120
poisson strain, 373
rosette, 374
shearing strain, 373
Wheatstone bridge, 375
strain relief, 20, 335
stress (strain gage), 373
string parameters, 301
strip length, wiring, 20
sweep (scan), defined, 78, 80
switch contact resistance, 399
switch life, 399
switch types
form C (SPDT), 59
matrix, 59
multiplexer, 58, 378
switching, errors, 381
syntax, SCPI conventions, 73, 181
system cabling, 55, 335
system clock
factory setting, 145
setting the, 22, 145
system speeds, 408
SYSTem:ALARm? command, 251, 268
SYSTem:CPON command, 260, 295
SYSTem:CTYPe? command, 265
SYSTem:DATE command, 264
SYSTem:ERRor? command, 268, 304
SYSTem:INTerface command, 269
SYSTem:LOCal command, 269
SYSTem:PRESet command, 161, 267
SYSTem:REMote command, 269
SYSTem:RWLock command, 269
SYSTem:TIME command, 264
SYSTem:TIME:SCAN? command, 236
SYSTem:VERSion?, 268, 295
SYSTem:VERSion? command, 268
T
TEMP:TRAN:FRTD:RES command, 222
TEMP:TRAN:FRTD:TYPE command, 222
TEMP:TRAN:RTD:RES command, 222
TEMP:TRAN:RTD:TYPE command, 222
TEMP:TRAN:TC:CHECk command, 221
TEMP:TRAN:TC:RJUN command, 221
TEMP:TRAN:THER:TYPE command, 222
TEMP:TRAN:TC:RJUN:TYPE command, 220
TEMP:TRAN:TC:TYPE command, 220
TEMP:TRAN:TYPE command, 219
temperature coefficient, 366
temperature conversion accuracy, 345
temperature measurements
RTDs, 110
thermistors, 112
thermocouples, 107
temperature units, 106
temperature, product operating, 408
terminal connections
ac current, 21
ac voltage, 21
ac current, 21
dc voltage, 21
frequency, 21
period, 21
resistance, 21
RTDs, 21
thermistors, 21
thermocouples, 21
wire strain relief, 20
wire strip length, 20
thermal EMF errors, 340
thermocouple, metals used, 351
thermistors
connections, 21
conversion accuracy, 345
measurement tutorial, 112, 346
measurement units, 106
types supported, 21, 106
Index
Index
431