RMON Commands
210 Intel® Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide
The following table describes the significant fields shown in the display:
rmon event
The rmon event Global Configuration mode command configures an event. To remove an
event, use the
no form of this command.
Syntax
rmon event index type [community text] [description text] [owner name]
no rmon event index
Parameters
index — Specifies the event index. (Range: 1-65535)
type — Specifies the type of notification generated by the device about this event.
Possible values:
none, log, trap, log-trap.
Field Description
Alarm Alarm index.
OID Monitored variable OID.
Last Sample Value The statistic value during the last sampling period. For example, if the sample
type is delta, this value is the difference between the samples at the beginning
and end of the period. If the sample type is absolute, this value is the sampled
value at the end of the period.
Interval The interval in seconds over which the data is sampled and compared with the
rising and falling thresholds.
Sample Type The method of sampling the variable and calculating the value compared
against the thresholds. If the value is absolute, the value of the variable is
compared directly with the thresholds at the end of the sampling interval. If the
value is delta, the value of the variable at the last sample is subtracted from
the current value, and the difference compared with the thresholds.
Startup Alarm The alarm that may be sent when this entry is first set. If the first sample is
greater than or equal to the rising threshold, and startup alarm is equal to
rising or rising and falling, then a single rising alarm is generated. If the first
sample is less than or equal to the falling threshold, and startup alarm is equal
falling or rising and falling, then a single falling alarm is generated.
Rising Threshold A sampled statistic threshold. When the current sampled value is greater than
or equal to this threshold, and the value at the last sampling interval is less
than this threshold, a single event is generated.
Falling Threshold A sampled statistic threshold. When the current sampled value is less than or
equal to this threshold, and the value at the last sampling interval is greater
than this threshold, a single event is generated.
Rising Event The event index used when a rising threshold is crossed.
Falling Event The event index used when a falling threshold is crossed.