Intel SBCEGBESW1 Switch User Manual


 
SNMP Commands
248 Intel® Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide
auth — Indicates authentication of a packet without encrypting it.
priv — Indicates authentication of a packet with encryption.
port — Specifies the UDP port of the host to use. If unspecified, the default UDP port
number is 162.
(Range: 1-65535)
filtername—Specifies a string that defines the filter for this host. If unspecified,
nothing is filtered.
(Range: 1-30 characters)
seconds — Specifies the number of seconds to wait for an acknowledgment before
resending informs. If unspecified, the default timeout period is 15 seconds. (Range: 1-
300)
retries — Specifies the maximum number of times to resend an inform request. If
unspecified, the default maximum number of retries is 3. (Range: 0-255)
Default Configuration
This command has no default configuration.
Command Mode
Global Configuration mode
User Guidelines
A user and notification view are not automatically created. Use the snmp-server user,
snmp-server group and snmp-server view Global Configuration mode commands to
generate a user, group and notify group, respectively.
Example
The following example configures an SNMPv3 host.
snmp-server trap authentication
The snmp-server trap authentication Global Configuration mode command enables the
device to send SNMP traps when authentication fails. To disable SNMP failed
authentication traps, use the
no form of this command.
Syntax
snmp-server trap authentication
Console(config)#
snmp-server v3-host
192.168.0.20 john
noauth