Intel SBCEGBESW1 Switch User Manual


 
802.1x Commands
394 Intel® Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide
The following table describes significant fields shown above:
* Port is down or not present.
Console# show dot1x ethernet ext.3
802.1x is enabled.
Port Admin Mode Oper Mode Reauth
Control
Reauth
Period
Username
---- ---------- --------- ------- ------ --------
3 Auto Unauthorized Ena 3600 Clark
Quiet period: 60 Seconds
Tx period:30 Seconds
Max req: 2
Supplicant timeout: 30 Seconds
Server timeout: 30 Seconds
Session Time (HH:MM:SS): 08:19:17
MAC Address: 00:08:78:32:98:78
Authentication Method: Remote
Termination Cause: Supplicant logoff
Authenticator State Machine
State: HELD
Backend State Machine
State: IDLE
Authentication success: 9
Authentication fails: 1
Field Description
Port The port number.
Admin mode The port admin mode. Possible values: Force-auth, Force-unauth, Auto.
Oper mode The port oper mode. Possible values: Authorized, Unauthorized or Down.
Reauth Control Reauthentication control.
Reauth Period Reauthentication period.