Lincoln Electric SVM112-B Power Supply User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
POWER WAVE 450
F-68 F-68
TROUBLESHOOTING & REPAIR
FIELD EFFECT TRANSISTOR/SWITCH BOARD TEST (continued)
TABLE F.3 – SWITCH BOARD 2 RESISTANCE TEST TABLE (Continued)
Apply Apply
Positive Negative
Test Test
Probe to Probe to Test Repair Next
Terminal Terminal Result Conclusion Action Procedure
12B 1B Less than OK None Continue
100 ohms
Greater Open Replace 4 Snubber
than 1K Switch Resistor
ohm Boards Test
1B 12B Greater OK None Continue
than 1K
ohm
Less than Shorted Replace 4 Snubber
100 ohms Switch Resistor
Boards Test
12B 403 Greater OK None Continue
than 1K
ohm
Less than Shorted Replace 4 Snubber
100 ohms Switch Resistor
Boards Test
403 12B Less than OK None Continue
100 ohms
Greater Open Replace 4 Snubber
than 1K Switch Resistor
ohm Boards Test
9B 404 Less than OK None Continue
100 ohms
Greater Open Replace 4 Snubber
than 1K Switch Resistor
ohm Boards Test
404 9B Greater OK None Continue
than 1K
ohm
Less than Shorted Replace 4 Snubber
100 ohms Switch Resistor
boards Test
NOTE: K ohm = ohm reading multiplied by 1000.
NOTE: Always make sure that all four Switch Boards are changed at the same time. Never
mix an old style (different part number) Switch Board with a new style (new part
number).