Lincoln Electric SVM112-B Power Supply User Manual


 
MAKE SURE FILTER CAPACITORS ARE
DISCHARGED
1. Construct a 115VAC pretest power supply
as per Figure F.78 using the following:
Switch (SPST)
Fuse (5 amp max)
P70 adapter
ALL AC SUPPLIES MUST BE ELECTRICAL-
LY ISOLATED (isolation transformers). THE
PRINTED CIRCUIT BOARDS WILL BE
DAMAGED IF THE AC SUPPLIES ARE NOT
ISOLATED.
WARNING
TROUBLESHOOTING & REPAIR
F-201 F-201
POWER WAVE 450
PRE-POWERUP SWITCH BOARD TEST PROCEDURE
FOR REPLACEMENT OF SWITCH ASSEMBLY G2402-2 (continued)
9L
400 VDC
VOLTMETER
R 9
12L
+
9M
400 VDC
VOLTMETER
R 10
12M
+
WARNING
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
FIGURE F.77 - FILTER CAPACITOR VOLTAGE