Lincoln Electric SVM112-B Power Supply User Manual


 
Input Voltages:
200 230 400 460 575
Input Currents
@ 500A/40 VDC 87 76 44 38 32
@ 450A/38 VDC 75 65 38 32 28
Duty Cycle
Amps Volts at Rated
Amperes
60% Duty Cycle 500 40 VDC
100% Duty Cycle 450 38 VDC
Constant Open Continuous Process
Circuit V
oltage Current Range Current Ranges
75 Volts 5-540 Amps GMAW 50-540 Amps
FCAW 40-540 Amps
STICK 30-540 Amps
Pulse Pulse Pulse and Background Pulse
Current Range Voltage Range Time Range Frequency
5-750 Amps 5-55 Volts 100 Microsec - 3.3 Sec 0.15 - 1000 Hz
Type 75°C Type 75°C Type 75°C
Input Duty Input Ampere Copper Wire in Ground Wire in (Super Lag)
Voltage/ Cycle
Rating on Conduit Conduit or Breaker
Freqency Nameplate AWG[IEC] AWG[IEC] Size (Amps)
Sizes (MM
2
) Sizes (MM
2
)
200/50-60 60% 87 4 (25) 8 (10) 120
230/50-60 60% 76 4 (25) 8 (10) 100
400/50-60 60% 44 8 (10) 10 (6) 50
460/50-60 60% 38 8 (10) 10 (6) 50
575/50-60 60% 32 8 (10) 10 (6) 50
200/50-60 100% 75 4 (25) 8 (10) 100
230/50-60 100% 65 4 (25) 8 (10) 100
400/50-60 100% 38 8 (10) 10 (6) 50
460/50-60 100% 32 8 (10) 10 (6) 50
575/50-60 100% 28 8 (10) 10 (6) 40
Height
Width Depth Weight
905 mm 515 mm 1010 mm 137.9 kg
35.6 in. 20.3 in. 39.8 in. 303.5 lbs.
0° to 40°C -50° to 85°C
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
INSTALLATION
A-2 A-2
POWER WAVE 450
TECHNICAL SPECIFICATIONS - POWER WAVE 450
INPUT -THREE PHASE ONLY
RATED OUTPUT
RECOMMENDED INPUT WIRE AND FUSE SIZES
PHYSICAL DIMENSION