Lincoln Electric SVM112-B Power Supply User Manual


 
F-73 F-73
IGBT/SWITCH BOARD TEST (G3165-1)
TABLE F.6 – NOTE: This test will NOT determine if an individual IGBT device is open.
TROUBLESHOOTING & REPAIR
POWER WAVE 450
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
Apply Apply
Positive Negative
Test Test
Probe to Probe to Test Repair Next
Terminal Terminal Result Conclusion Action Procedure
2/4 12 Greater than OK None Continue
1k ohms
Less Shorted Replace Snubber
than 1K Switch Resistor
ohms Boards Test
9 1/3 Greater OK None Continue
than 1K
ohms
Less than Shorted Replace Snubber
1k ohms Switch Resistor
Boards Test
2/4 9 Less OK None Continue
than 100
ohms
Greater than Open Replace Snubber
1k ohms Switch Resistor
Boards Test
9 2/4 Greater than OK None Continue
1k ohms
Less Shorted Replace Snubber
than 1K Switch Resistor
ohms Boards Test
NOTE: K ohm = ohm reading multiplied by 1000.
NOTE: Always make sure that all four Switch Boards are changed at the same time. Never
mix an old style (different part number) Switch Board with a new style (new part
number).