OPERATION
B-21 B-21
POWER WAVE 450
Trigger
Position
1
GMAW GMAW STICK
1
GMAW GMAW
Pulse FCAW Pulse FCAW
WFS DISPLAY: WFS DISPLAY:
Wire Feed Speed Wire Feed Speed
WFS and WFS and Preset VOLTAGE VOLTAGE
Open Arc Length Trim Preset Voltage Current DISPLAY: DISPLAY:
Arc Length Trim Preset Voltage
WFS, WFS, WFS DISPLAY: WFS DISPLAY:
Actual Arc Actual Arc Preset Current, Wire Feed Speed Wire Feed Speed
2
Closed Voltage, Voltage, Actual Arc VOLTAGE VOLTAGE
Actual Arc Actual Arc Voltage, Actual DISPLAY: DISPLAY:
Current Current Arc Current Actual Arc Voltage Actual Arc Voltage
1
In Stick, trigger is on Remote Control Kit K941-1.
2
Arc Current, not wire feed speed, is displayed if a Remote Control Kit is attached to the wire feeder.
Power Wave 450
Wire Feeder
Arc Length Trim Preset Arc Length
0.6 60% of preset length
0.8 80% of preset length
1.0 no change to preset length
1.2 120% of preset length
1.4 140% of preset length
TABLE B.6 – RELATIONSHIP BETWEEN
SELECTED ARC LENGTH TRIM AND PRESET
ARC LENGTH AS INDICATED BY ARC LENGTH
TABLE B.3 – RELATIONSHIP BETWEEN
VOLTAGE TRIM AND PRESET VOLTAGE
Voltage Trim Relationship to Preset Voltage
0.6 60% of preset voltage
0.8 80% of preset voltage
1.0 no change to preset voltage
1.2 120% of preset voltage
1.4 140% of preset voltage
Explanation of Table B.3:
If, for example, the minimum voltage trim is set to 0.8
and the maximum voltage trim is set to 1.4, this
means that the voltage for a given wire feed speed
can be adjusted to be anywhere between 80% and
140% of the preset voltage of that wire feed speed.
Adjustable GMAW GMAW
Parameters Pulse FCAW Stick
Wire Feeder Wire Feed Wire Feed
WFS Display Speed Speed
Wire Feeder Arc Length Preset
Voltage Display Trim Voltage
Power Wave 450 Display
(with GMAW Pulse, Wave Wave Wave
GMAW FCAW, Stick Control Control Control
Process Selection Overlay) (Frequency) (Inductance) (Arc Force)
TABLE B.4 – ADJUSTABLE PARAMETERS
TABLE B.5 – DISPLAYS OF THE POWER WAVE AND WIRE FEEDERS
FOR DIFFERENT PROCESSES IN BOTH TRIGGER POSITIONS