LSI 53C810A Computer Hardware User Manual


 
7-4 Electrical Characteristics
Table 7.6 Capacitance
Symbol Parameter Min Max Unit Test Conditions
C
I
Input capacitance of input pads 7 pF
C
IO
Input capacitance of I/O pads 10 pF
Table 7.7 Output Signals—MAC/_TESTOUT, REQ/
Symbol Parameter Min Max Unit Test Conditions
V
OH
Output high voltage 2.4 V
DD
V 16 mA
V
OL
Output low voltage V
SS
0.4 V 16 mA
I
OH
Output high current 8 mA V
DD
0.5 V
I
OL
Output low current 16 mA 0.4 V
I
OZ
3-state leakage 10 10 µA–
Note: REQ/ has a 100 µA pull-up that is enabled when TESTIN is low.
Table 7.8 Output Signal—IRQ/
Symbol Parameter Min Max Unit Test Conditions
V
OH
Output high voltage 2.4 V
DD
V 8mA
V
OL
Output low voltage V
SS
0.4 V 8 mA
I
OH
Output high current 4 mA V
DD
0.5 V
I
OL
Output low current 8 mA 0.4 V
I
OZ
3-state leakage 10 10 µA–
Note: IRQ/ has a 100 µA pull-up that is enabled when TESTIN is low. IRQ/ can be enabled with a
register as an open drain with an internal 100 µA pull-up.