LSI 53C810A Computer Hardware User Manual


 
DC Characteristics 7-5
Table 7.9 Output Signal—SERR/
Symbol Parameter Min Max Unit Test Conditions
V
OL
Output low voltage V
SS
0.4 V 16 mA
I
OL
Output low current 16 mA 0.4 V
I
OZ
3-state leakage 10 10 µA–
Table 7.10 Bidirectional Signals—AD[31:0], C_BE/[3:0], FRAME/, IRDY/, TRDY/,
DEVSEL/, STOP/, PERR/, PAR/
Symbol Parameter Min Max Unit Test Conditions
V
IH
Input high voltage 2.0 V
DD
+0.5 V
V
IL
Input low voltage V
SS
0.5 0.8 V
V
OH
Output high voltage 2.4 V
DD
V16mA
V
OL
Output low voltage V
SS
0.4 V 16 mA
I
OH
Output high current 8 mA V
DD
0.5
Note: All the signals in this table have 100 µA pull-ups that are enabled when TESTIN is low.