Installing and Cabling the Cabinets
134 Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
Figure 62: Connections for 1 to 8 Out-of-Building Analog Telephones
Figure 63 shows the connections for up to 24 off-premises analog telephones. Concentrations
of analog line pairs are used at both buildings to minimize the off-premises wiring required. At
the MDF, jumpers must be connected between 1 row/connecting block in the white field and up
to 3 rows/connecting blocks in the purple field. At the station location, a WP-90929, List 1
Concentrator Cable is used. There are 8 station appearances on each of the 3 fingers of the
concentrator cable.
Figure notes:
1. Locally engineered cables
2. Out-of-building wiring
3. Multi-pair protector units (primary
protectors with heat coils or equivalent
with sneak current protection)
4. 356A adapter
5. B25A cable
6. Out-of-building analog telephones
7. Part of MDF
8. Station side (white field)
9. System side (purple field)
10. Cross-connect jumpers
11. To analog line circuit pack (TN2183,
TN769, or TN746B)