Avaya CMC1 Network Router User Manual


 
Add DS1 Tie and OPS
Issue 10 June 2005 255
Add DS1 Tie and OPS
The TN2313AP DS1 Tie Trunk and TN767B (or later) DS1 Interface circuit packs provide
connections to a 1.544 Mbps DS1 facility (T1) as 24 independent
64 Kbps trunks.
The TN2313AP DS1 Tie Trunk, TN767B (or later) DS1 Interface, and TN464HP DS1 Interface
circuit packs provide connections to a 2.048 Mbps DS1 facility (E1) as 32 independent 64-kbps
trunks.
Service Interruption
To add DS1 tie and OPS trunks:
1. Since the addition of DS1 tie-trunk service may require a service interruption, notify the
customer in advance as to when the addition will occur.
2. For information about administering DS1 Tie Trunks, refer to Administrator’s Guide for
Avaya Communication Manager.
Table 55: Tie Trunk Option-Switch Settings and Administration
Installation Situation Preferred Signaling
Format
E&M/SMPLX
Switch
Prot/Unprot
Switch
Administered
Port
Circumstance To System Far-End
Collocated Avaya
CMC1
Media
Gateway
E&M Type
1
E&M Type
1
E&M Unprotected Type 1
Compatible Standard Compatible
Inter-Building Avaya
CMC1
Media
Gateway
Protected
Type 1
Protected
Type 1
E&M Protected Type 1
Compatible Standard
Plus
Compatible
Protection
Unit
Collocated Net
Integrated
E&M Type
1
Any PBX E&M Unprotected Type 1
Standard