Adding or Removing Hardware
316 Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
Figure 97: Typical nonsignaling wideband configuration
If using a CSU, the distance between connections may be up to 1300 ft. (397.2 m). The
maximum distance to the endpoint depends on the type of cable and the specifications of the
endpoint.
Signaling configuration
A signaling connection from the system to a wideband endpoint passes through a bandwidth
controller. The distance between the system and the bandwidth controller depends on the type
of cable and controller. Figure 98
shows connections with and without a CSU.
Figure notes:
1. Wideband endpoint (wire per manufacturer)
2. Modular cord
3. 103A or modular wall jack
4. Channel service unit (CSU)
5. H600-307 cable to DTE connector on CSU
6. DS1/E1 circuit pack
7. Main distribution frame (MDF)
8. Distance limit depends on cable and
endpoint type.
9. A25D 25-pair cable (male-to-male)
cydf049 RPY123097
AUX PORTCOM PORT MODEM
DTE
NETWOR K
POWER
1
1
2
2
3
3
4
5
6
6
7
8
9