Adding or Removing Hardware
308 Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
Testing
1. On the system management terminal, press ENTER to get the login prompt to the
Communication Manager switch.
Note:
Note: If you get garbled text, check the baud rate setting on the Port Setup Menu. You
can adjust it up or down.
2. If no login prompt appears, log back into the IOLAN+ through HyperTerminal.
3. Select Admin mode > stats and press ENTER twice.
4. Select users and press ENTER.
5. Look at the port that the adjunct is connected to and see if there is any traffic. If not, check
all your connections and administration fields.
After you have successfully administered and validated the connection between the adjunct and
the C-LAN circuit pack through the IOLAN+, you can disconnect the laptop or other PC from the
IOLAN+. No further IOLAN+ administration is required.
Potential failure scenarios and repair actions
If a link goes down between the terminal server and the switch, you must reboot the terminal
server for the link come back up. If you are performing a software upgrade or if a system reset
occurs, you must reboot the terminal server to restore the link. See Rebooting the IOLAN+
on
page 305 for instructions.
** Administrator ** SERVER STATISTICS Terminal: 2
1. port1 Talking to host 172.22.22.67.5111<DSR+CTS+DCD >DTR+RTS
2. port 2 SERVER STATISTICS <DSR+DCD >DTR+RTS
3. port 3 waiting for DSR or DCD >DTR+RTS
4. port 4 modem waiting for DSR or DCD >DTR+RTS
REM <unknown> logged out
LOG logger not enabled
________________________________________________________________________________
Press <RETURN> to see list of options.
IOLAN PLUS v4.02.00 a CDi iolan-st