4.3.6.4 exec-timeout
Use this command to set the interval that the system waits for user input before
terminating the current session. Use the no form to restore the default.
Syntax
exec-timeout [seconds]
no exec-timeout
seconds - Integer that specifies the number of seconds.
(Range: 0 - 65535 seconds; 0: no timeout)
Default Setting
CLI: No timeout
Telnet: 10 minutes
Command Mode
Line Configuration
Command Usage
If user input is detected within the timeout interval, the session is kept open;
otherwise the session is terminated.
This command applies to both the serial console and Telnet connections (but
you cannot disable the timeout for Telnet).
Example
To set the timeout to two minutes, enter this command:
4.3.6.5 password-thresh
Use this command to set the password intrusion threshold that limits the number of
failed login attempts. Use the no form to remove the threshold value.
Console(config-line)#exec-timeout 120