Sunfire B1600 Switch User Manual


 
4-84 Sun Fire B1600 Blade System Chassis Switch Administration Guide June 2003
ethernet port-name
port-name down link: SNP0-15; up link: NETP0-7; mgt: NETMGT
port-channel channel-id (Range: 1 to 6)
vlan vlan-id (Range: 1 to 4094)
Default Setting
None
Command Mode
Global Configuration
Example
To specify the first up-link port, enter the following command:
4.3.8.2 description
Use this command to add a description to an interface. Use the no form to remove
the description.
Syntax
description string
no description
string – A comment or a description to help you remember what is attached to
the interface. (Range: 1 to 64 characters)
Default Setting
NETP0-7: External RJ-45 connector NET0-7
SNP0-15: Blade Slot 0-15
NETMGT: External RJ-45 connector NETMGT
Console(config)#interface ethernet NETP0
Console(config-if)#