Sunfire B1600 Switch User Manual


 
4-166 Sun Fire B1600 Blade System Chassis Switch Administration Guide June 2003
Command Mode
Privileged Exec
Command Usage
This command displays the currently configured source port, destination port,
and mirror mode (RX, TX, RX/TX).
Example
The following shows mirroring configured from port SNP6 to port NETP2:
Related Commands
port monitor (4-164)
4.3.17 Link Aggregation Commands
Ports can be statically grouped into an aggregated link to increase the bandwidth of
a network connection or to ensure fault recovery. Or you can use the Link
Aggregation Control Protocol (LACP) to negotiate a dynamic aggregated link
between this switch and another network device. For static aggregated links, the
switches connected to must be of the same type. But for dynamic aggregated links,
the switches simply have to comply with LACP. This switch supports up to six
Console(config)#interface ethernet NETP2
Console(config-if)#port monitor ethernet SNP6
Console(config-if)#end
Console#show port monitor
Port Mirroring
-------------------------------------
Destination port(listen port):NETP2
Source port(monitored port) :SNP6
Mode :RX/TX
Console#