3-10 Sun Fire B1600 Blade System Chassis Switch Administration Guide • June 2003
3.2.1.2 Command-line Interface: Displaying and Specifying
Identification Details
FIGURE 3-4 CLI Commands for Specifying Host Name, Location, and Contact
Information.
Console(config)#hostname R&D 5
Console(config)#snmp-server location WC 9
Console(config)#snmp-server contact Charles
Console#show system
System description: Sun Fire B1600
System OID string: 1.3.6.1.4.1.674.10895.4
System information
System Up time: 0 days, 0 hours, 55 minutes, and 54.91 seconds
System Name : [NONE]
System Location : [NONE]
System Contact : [NONE]
MAC address : 00-00-e8-00-00-01
Web server : enable
Web server port : 80
Web secure server : enable
Web secure server port : 443
POST result
--- Performing Power-On Self Tests (POST) ---
UART Loopback Test ..................... PASS
Timer Test ............................. PASS
DRAM Test .............................. PASS
I2C Initialization ..................... PASS
Runtime Image Check .................... PASS
PCI Device Check ....................... PASS
Switch Driver Initialization ........... PASS
------------------- DONE --------------------
Console#