Intel 80C186XL Computer Hardware User Manual


 
INSTRUCTION SET DESCRIPTIONS
C-24
JNE
JNZ
Jump on Not Equal:
Jump on Not Zero:
JNE
disp8
JNZ
disp8
Transfers control to the target location
if the tested condition (ZF = 0) is true.
Instruction Operands:
JNE short-label
JNZ short-label
if
(ZF) = 0
then
(IP) (IP) + disp8 (sign-ext to 16 bits)
AF
CF
DF
IF
OF –
PF
SF
TF
ZF
JNO Jump on Not Overflow:
JNO
disp8
Transfers control to the target location
if the tested condition (OF = 0) is true.
Instruction Operands:
JNO short-label
if
(OF) = 0
then
(IP) (IP) + disp8 (sign-ext to 16 bits)
AF
CF
DF
IF
OF –
PF
SF
TF
ZF
JNS Jump on Not Sign:
JNS
disp8
Transfers control to the target location
if the tested condition (SF = 0) is true.
Instruction Operands:
JNS short-label
if
(SF) = 0
then
(IP) (IP) + disp8 (sign-ext to 16 bits)
AF
CF
DF
IF
OF –
PF
SF
TF
ZF
JNP
JPO
Jump on Not Parity:
Jump on Parity Odd:
JNO
disp8
JPO
disp8
Transfers control to the target location
if the tested condition (PF=0) is true.
Instruction Operands:
JNO short-label
JPO short-label
if
(PF) = 0
then
(IP) (IP) + disp8 (sign-ext to 16 bits)
AF
CF
DF
IF
OF –
PF
SF
TF
ZF
Table C-4. Instruction Set (Continued)
Name Description Operation
Flags
Affected
NOTE: The three symbols used in the Flags Affected column are defined as follows:
– the contents of the flag remain unchanged after the instruction is executed
? the contents of the flag is undefined after the instruction is executed
the flag is updated after the instruction is executed