Sony MVS8000 Switch User Manual


 
151Digital Multi Effects (DME)
Chapter 1 MVS-8000 Functions
Invert
Inverts the input video signal and/or key signal horizontally or vertically. You
can make separate settings for the front and back.
Inversion of input signal
Interpolation
Specifies the methods used for interpolation processing of input video signals
and input key signals.
For input video signals, you can select from the following four methods.
Detect changes in the luminance and chrominance signals separately, and
switch automatically between fields and frames. You can select the degree of
change detection.
Detect changes in the luminance signal separately, and switch automatically
between fields and frames. You can select the degree of change detection.
Do interpolation in field units.
Do interpolation in frame units.
For input key signals, you can select from the following three methods.
Detect changes in the luminance signal separately, and switch automatically
between fields and frames. You can select the degree of change detection.
Do interpolation in field units.
Do interpolation in frame units.
You can also select the number of pixels used in interpolation processing, and
select the method used to show the picture reduced or expanded.
Further, you can apply an anti-moire filter to reduce the moire patterns created
by interpolation.
Notes
Interpolation processing is possible for the following signal formats and
DME systems.
Horizontal inversion
Input signal
Vertical inversion