Sony MVS8000 Switch User Manual


 
189Setup
Chapter 1 MVS-8000 Functions
The actual operation is linked between the top and bottom rows of the table
(e.g. M/E-3 and M/E-1), but the common setting values cannot be used
between the two screen aspect ratios. The edges of the screen, for example,
differ between 16:9 and 4:3.
For image operations in the device control block, first make the settings
separately on the different channels.
Recalling a user programmable DME: When recalling a user programmable
DME, select pattern numbers 1901 to 1949, 2901 to 2949, or 3901 to 3949.
The effects for the 16:9 and 4:3 screen aspect ratios will be recalled linked
together.
Signal format settings (Format)
Make the following settings.
Signal format
Specify the signal format to be handled by the devices.
The combinations of signal formats that can be selected are as follows.
Software options for multi-format
To use the MVS-8000G with multi-format support requires the following
software options.
151 to 199,
251 to 299,
351 to 399
4:3 M/E-1 M/E-2 Ch3 Ch4
Register
numbers
Screen aspect
ratio
Switcher bank Channel
System Field frequency Effective number of scan lines
HD system 50 1080i
59.94
60
23.976 1080PsF
24
25
29.97
30
50 720P
59.94
SD system 59.94 480i
50 576i